What was found
PD: AFTER MAKING SRV AMT FOUND NEW INNER WALL WAS MANUFACTURED INCORRECTLY. BOTH WELD/COOLING PORTS WERE INSTALLED IN THE WRONG POSITION. CA: ***LIMITED RELEASE, RVDT WAS REMOVED AND REINSTALLED DURING MAINTENANCE, VERIFY CORRECT RVDT RIG/READINGS IAW AMM PROCEDURES.*** INSPECTED AND REPAIRED IAW CMM 78-31-76 OEM REV 42 DTD 11/01/18 & REV 25 DTD 11/27/18, CMM 78-31-77 OEM REV 42 DTD 11/01/18 & DAL REV 26 DTD 11/27/18. AA 7830-01331 REV D SECT. 4, 7,8,9 & 10 WERE COMPLIED WITH ON SHOP ORDER PS6628. *****#1 RT THRUST REVERSER**** ***LIMITED RELEASE, RVDT WAS REMOVED AND REINSTALLED DURING MAINTENANCE, VERIFY CORRECT RVDT RIG/READINGS IAW AMM PROCEDURES.*** INSPECTED AND REPAIRED IAW CMM 78-31-76 OEM REV 42 DTD 11/01/18 & DAL REV 25 DTD 11/27/18, CMM 78-31-77 OEM REV 42 .