What was found
A/C 3122 CLOSED LOG 6605550 FLT/CHK 0839. ON THE GROUND WITH ALL CARGO DOORS CLOSED SMOKE AFT CARGO SMOKE ALARM. ECAM QRH FIRE BOTTLE WAS DISCHARGED. FIRE DEPARTMENT OPENED DOOR. EXAMINED AREA NO ABNORMALITIES FOUND. REMOVED AND REPLACED CARGO FIRE EXTINGUISHER BOTTLE. ALL TEST PASSED, RFID TAGS INSTALLED. REF A319 AMM 26-23. MEL AND PLACARD REMOVED. EXTINGUISHER, F OFF 32-2620-9-0006 96291 ON 32-2620-9-0006 56301