What was found
CORROSION LEVEL: 2. CORROSION FLOOR BEAM -Y1292 BRW FR68 TO FR69 AT AFT GALLEY AREA (SSI 534147). REPLACED FLOOR BEAM -Y1292 LOCATED BTW FR68 TO FR69 AT AFT GALLEY AREA AS PER A319 SRM 51-72-11 AND DRAWING #53472089 ISSUE:A, RELEASE DATE:02-OCT-13, SRM A319 51-42-11. MEASURE OF CORROSION ARE: L=0.762", W=0.498", D=0.070".