As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FLOOR STRUCTURE BEAM LOCATED BTW FR 66 TO FR 67+18 INCH AND -Y 1292 IN PASSENGER CABIN (1 EA), REPLACED FLOOR BEAM LOCATED BTW FR.66 TO FR.67+18 INCH AND -Y1292 IN PASSENGER CABIN (1E/A) AS PER A320 SRM 51-72-11 AND DWG#53472780