What was found
DRAWING 16D12N00101, SHEET 3, FOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 654A+44 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350862)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DRAWING 16D12N00101, SHEET 3, FOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 654A+44 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350862)