Service difficulty report · Bulb · Doug MD88

Difficulty date
November 27, 2019
Submitted
November 29, 2019
Operation
Air carrier
Aircraft
N973DL
Make and model
Doug MD88
Aircraft serial
53241
Aircraft time
74,948 hours, 55,858 cycles
Part
Bulb
Condition
Burned Out
Location
Lavatory Light
Stage of operation
NR
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER FLIGHT F/A REPORTED LEFT AFT LAV SMOKE DETECTOR WENT OFF IN FLIGHT. ONE PAX REPORTED SMELLING SOMETHING. IN FLIGHT F/A REPORTED WHAT PAX SAID I ASKED FOR DETAILS, SHE SAID SHE SMELLED NOTHING; AND NO REPORT OF ALARM. ONLY AFTER WE DEPLANED DID SHE TELL ME ABOUT THE ALARM. COMPLIED WITH NO GO ODI PREVENTION ATA 2172. COMPLIED WITH PNEUMATIC DIST. CABIN SMOKE/ODOR WORKCARD 2120-2367. NO DEFECTS NOTED. COMPLIED WITH WORKCARD 7100-2619 - PNEUMATIC SYSTEM DUCT BURNOUT. REMOVED AND REPLACED LEFT AFT LAV MIRROR LIGHT BULBS PER MD88 33-22. OPS CHECK GOOD. INSPECTED LEFT AFT + RIGHT AFT LAV TRASH BINS. NO DEFECTS NOTED. AFT LAV SMOKE DETECTORS OPS CHECK GOOD IN REFERENCE TO MD88 AMM 26-13. OK FOR SERVICE. (LP6544408)