As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK INDICATION ON INTERCOSTAL FITTING IN OPEN FASTENER HOLE AT LEVEL OF DOOR STOP #7 R/H FR16 AT FWD GALLEY AREA (1 EA). REPLACED INTERCOSTAL FITTING LOC AT LEVEL DOOR STOP 7 RH BTW FR 15 TO FR 16 AS PER A319 SRM 51-72-11 AND DRAWING D531-12300.