As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK INDICATION ON FRAME FR16 RH SIDE, DOOR STOP 7 HOLE 3 (LOW/ INB). CRACK AT 10 O CLOCK ON UPPER FUSELAGE (1 EA). PERFORMED ROTOTEST INSPECTION ON FITTING AND FRAME OF DOOR STOP #7 RH SIDE AND FOUND CRACK INDICATION ONLY IN FITTING AS PER NTM 51-10-01. REPLACED FITTING LOC. AT LEVEL OF DOOR FR 16 DOOR STEP #7 AS PER A319 SRM 51-72-11 AND DWG D53112300.