As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION LEVEL: 2. CORROSION INTERNAL STRUCTURE SUPPORT WEB LOCATED UNDER FLOOR STRUCTURE BTW FR 69 TO FR 70 AND STR 23L TO STR 24L IN BULK CARGO COMPARTMENT (1 EA) (SSI 534144). REPLACED WEB LOCATED UNDER FLOOR STRUCTURE BTW FR 69 TO FR 70 AND STR 23L TO STR 24L BULK CARGO COMPARTMENT PER SRM A319 51-42- 11 SRM 51-72-11 DWG # D53470100. MEASURE OF CORROSION L=3.00" W=2.160" D=0.030".