As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION LEVEL: 2. CORROSION INTERNAL STRUCTURE SUPPORT WEB LOCATED UNDER FLOOR STRUCTURE BTW FR 69 TO FR 70 AND STR 23R TO STR 24R IN BULK CARGO COMPARTMENT (1 EA) (SSI 534144 ). REPLACED SUPPORT WEB LOCATED UNDER FLOOR STRUCTURE BETWEEN FR69 TO FR70 AND STR 23R TO STR 24R IN BULK CARGO COMPARTMENT ASPER SRM A319 51-42-11, SRM 51-72-11 AND DRAWING #D53470100. MEASUREMENTS OF CORROSION ARE: L=2.024" W=1.780", D=0.030".