FWD CARGO DOOR CORRODED AT CENTER LIGHT STRUCTURE LWR EDGE. FABRICATED AND INSTALLED NEW WEB AND LOWER TEE SUPPORT ON FWD CARGO DOOR IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO DOOR CORRODED AT CENTER LIGHT STRUCTURE LWR EDGE. FABRICATED AND INSTALLED NEW WEB AND LOWER TEE SUPPORT ON FWD CARGO DOOR IAW SRM 51-40-02.