What was found
AD/EM-EO TASK -OPEN HOLE HFEC INSPECTION FOUND 01 EA CRACK AT ABOUT 10 O'CLOCK POSITION (LOOKING FROM I/B ) ON THE LOWER OF THE THREE FASTENER HOLES IN THE RH STA955 FAIL SAFE STRAP AS MARK . LOG-PAGE UPDATED THE CRACK AT ABOUT 10 O'CLOCK POSITION (LOOKING FROM I/B ) ON THE LOWER OF THE THREE FASTENER HOLES IN RH STA955 FAIL SAFE STRAP REPAIRED AS PER W/C 5312-01170-10B-02 AND NRC 130-016 (1498929)