What was found
CRACK INDICATION ON FRAME 16 RH SIDE AT DOOR STOP FITTING 7, HOLE 1 AT FWD GALLEY AREA (1EA)(CRACK DIRECTION AT 8 O'CLOCK) AD RELATED JOB CARD 5311-01229-06. REPLACED INTERCOSTAL FITTING ON FRAME 16 RH SIDE AT DOOR STOP FITTING 7 AS PER SRM A319 51-72-11 AND DRAWING #D53112300. RII INSPECTION COMPLETE.