What was found
AD/EM-EO TASK -OPEN HOLE HFEC INSPECTION FOUND 01 EA CRACK AT ABOUT 10 O'CLOCK POSITION (LOOKING FROM I/B )ON THE LOWER OF THE THREE FASTENER HOLES IN THE RH STA 955 FAIL-SAFE STRAP AS MARK PER W/C 5312-01170-06 STEP 10 .AND TO REPAIR THE FAIL SAFE STRAP IN ACCORDANCE WITH EM 5312-01170 SECTION 10B PRIOR TO FURTHER FLIGHT . AD/EM-EO TASK -OPEN HOLE HFEC INSPECTION FOUND 01 EA CRACK AT ABOUT 10 O'CLOCK POSITION (LOOKING FROM I/B )ON THE LOWER OF THE THREE FASTENER HOLES IN THE RH STA 955 FAIL-SAFE STRAP AS MARK PER W/C 5312-01170-06 STEP 10 .AND TO REPAIR THE FAIL SAFE STRAP IN ACCORDANCE WITH EM 5312-01170 SECTION 10B PRIOR TO FURTHER FLIGHT . THE CRACK ON THE FAIL SAFE STRAP REPAIRED IN ACCCORDANCE WITH EM5312-01170 SECTION 10B. (1518248)