What was found
AD/EM-EO TASK -OPEN HOLE HFEC INSPECTION FOUND 01 EA CRACK AT ABOUT 5 O'CLOCK POSITION (LOOKING FROM I/B ) ON THE LOWER OF THE THREE FASTENER HOLES IN THE LH STA955 FAIL -SAFE STRAP AS MARK PER W/C 5312-01170-05 STEP 10 .AND TO REPAIR THE FAIL SAFE STRAP IN ACCORDANCE WITH EM 5312-01170 SECTION 10A PRIOR TO FURTHER FLIGHT . THE CRACK ON THE FAIL SAFE STRAP REPAIRED IN ACCORDANCE WITH EM5312-01170 SECTION 10A. (1518337)