What was found
ACCORDING TO THE AOS REPORT, EMERGENCY DECLARED - HYD R TEMP HI MESSAGE AFTER T/O. R&R RT ENG EDP PER B717 AMM 29-11. OPS AND LEAK CHK OK. ODI PAPERWORK C/W. PUMP, HYD, ENG 95-2911-9-0001 S/N 00019. (LP6906554)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ACCORDING TO THE AOS REPORT, EMERGENCY DECLARED - HYD R TEMP HI MESSAGE AFTER T/O. R&R RT ENG EDP PER B717 AMM 29-11. OPS AND LEAK CHK OK. ODI PAPERWORK C/W. PUMP, HYD, ENG 95-2911-9-0001 S/N 00019. (LP6906554)