What was found
CORROSION FLOOR BEAM -Y765 AT LEVEL FR20 AT FWD GALLEY AREA, REPLACED FLOOR BEAM -Y765 AT LEVEL FR.12 TO FR24 AT FWD GALLEY AREA ASPER SRM A320 FAM AMM 51-72-11 AND DWG D53112782
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FLOOR BEAM -Y765 AT LEVEL FR20 AT FWD GALLEY AREA, REPLACED FLOOR BEAM -Y765 AT LEVEL FR.12 TO FR24 AT FWD GALLEY AREA ASPER SRM A320 FAM AMM 51-72-11 AND DWG D53112782