What was found
THE FOLLOWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE DURING A SERVICE CHECK: - L1 & R1 EMERGENCY EXIT SIGNS, FAP PANEL EMERGENCY EXIT SIGN, AND THE CABIN OVERHEAD LIGHTS BETWEEN ROWS 24 THROUGH 29. MAINTENANCE REPLACED THE BATTERY PACKS B5-231, B5-118, AND B5-235 PER B717 AMM 33-51. OPERATIONAL CHECKS ARE NOW GOOD. (LP #7110689)