As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON SERVICE CHECK FOUND CREW REST FLOOR PROXY EMERGENCY LIGHTS AND L1 DOOR EXIT IDENTIFIER INOPERATIVE. REPLACED F3 FUSE AT M33093 EMERGENCY POWER SUPPLY. FOUND SHORT TO GROUND AT PIN 13. REMOVED 2ND STEP ACCESS PANEL IN THE CREW REST. LOWER THE PANEL ABOVE L1 DOOR. REPLACED SPLICES AT ALL LOWER CREW REST LIGHT ASSEMBLY. SYSTEM OPERATION IS NORMAL.