What was found
CRACK INDICATION ON FRAME 16 ON FASTENER HOLE NR 3 DOOR STOP 7 LT SIDE. CRACK DIRECTION 4 O`CLOCK AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED ROTOTEST INSPECTION ON AFFECTED HOLES NR 3 LOCATED DOOR STEP 01: AME 16 LT SIDE, AS PER NTM 51-10-01. CRACK INDICATION FOUND ONLY INTERCOSTAL FITTING. REPLACED INTERCOSTAL FITTING, REPLACED INTERCOSAL FITTING LOCATED FRAME 16 DOOR STEP 7 LT SIDE, AS PER A320 SRM 51-72-11 DWG D53112300 ISSUE HOO; RELEASE DATE: 30-JUN-98 AND PRI587655-14AD, REV.O AND ER/A 587655-14AD REV ORIGINAL.