What was found
WEAR ON FLOOR STRUCTURE BEAM LOCATED BETWEEN FR 12 TO FR 13 AND Y765 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM +Y765 LOC FR 12 TO FR 24 IN FWD GALLEY AREA, AS PER A319 SRM 51-72-11 AND DWG D53112812, ISSUE: E00, RELEASE DATE: 14-MAR-03