As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FLOOR STRUCTURE BEAM LOCATED BETWEEN FR 66 TO FR 68 Y1292 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM LOC BETWEEN FR 66 TO FR 68 Y1292 IN AFT GALLY AREA, AS PER SRM 51-72-11 AND DRAWING D53472000000, RELEASE DATE:06-JAN-03 ISSUE: DE