What was found
AFTER BLEND OUT AREA ON BEAM AT STA 1280 BETWEEN STR 9/10 RT THICKNESS ON FRAME STA 1280 BETWEEN S-9/10 RT WAS FOUND OUT OF LIMITS, NOM THICKNESS WAS 0.080" REMAINING THICKNESS IS 0.030. FRAME WAS REPAIRED, PER ERA 588417-14AD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER BLEND OUT AREA ON BEAM AT STA 1280 BETWEEN STR 9/10 RT THICKNESS ON FRAME STA 1280 BETWEEN S-9/10 RT WAS FOUND OUT OF LIMITS, NOM THICKNESS WAS 0.080" REMAINING THICKNESS IS 0.030. FRAME WAS REPAIRED, PER ERA 588417-14AD.