What was found
DURING INITIAL INSPECTION CORROSION LEVEL 2 FOUND ON FLOOR STRINGER RBL 2 FROM STA 1510 TO 1518 AT AFT CARGO COMPARTMENT (CCT). STRINGER REPAIRED, PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INITIAL INSPECTION CORROSION LEVEL 2 FOUND ON FLOOR STRINGER RBL 2 FROM STA 1510 TO 1518 AT AFT CARGO COMPARTMENT (CCT). STRINGER REPAIRED, PER SRM.