What was found
DURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS LBL 16.10, LBL 10.45, LBL 7.55 ALSO RBL 2.90, RBL 7.55, AND RBL 16.10, STA 653 AT FWD CARGO COMPARTMENT. STRINGER REPAIRED PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS LBL 16.10, LBL 10.45, LBL 7.55 ALSO RBL 2.90, RBL 7.55, AND RBL 16.10, STA 653 AT FWD CARGO COMPARTMENT. STRINGER REPAIRED PER SRM.