What was found
DURING INSPECTION FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS LBL 2.90 IN STA 1510 AT AFT CARGO COMPARTMENT. REPAIRED PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS LBL 2.90 IN STA 1510 AT AFT CARGO COMPARTMENT. REPAIRED PER SRM.