What was found
INITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR SUPPORT NEXT TO FLOOR STRINGER 10.45 RBL FROM STA 1460/1480 AT AFT CARGO COMPARTMENT. FLOOR SUPPORT REPAIRED, PER SRM 51-70-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR SUPPORT NEXT TO FLOOR STRINGER 10.45 RBL FROM STA 1460/1480 AT AFT CARGO COMPARTMENT. FLOOR SUPPORT REPAIRED, PER SRM 51-70-11.