What was found
DURING INITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR STRINGERS, RBL 7.55 AT STA 1333, STA 1362, STA 1374, RBL 10.45 AT STA 1360, STA 1371 AND RBL 16.10 AT STA 1374. STRINGERS REPAIRED PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR STRINGERS, RBL 7.55 AT STA 1333, STA 1362, STA 1374, RBL 10.45 AT STA 1360, STA 1371 AND RBL 16.10 AT STA 1374. STRINGERS REPAIRED PER SRM.