What was found
DURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SUPPORT TEE STA 1040, BETWEEN LBL 6 TO RBL 6 AT KEEL BEAM AREA. C/W ERA 589104-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SUPPORT TEE STA 1040, BETWEEN LBL 6 TO RBL 6 AT KEEL BEAM AREA. C/W ERA 589104-14.