Service difficulty report · Fault Message · Airbus A330323

Difficulty date
January 15, 2021
Submitted
January 19, 2021
Operation
Air carrier
Aircraft
N806NW
Make and model
Airbus A330323
Aircraft serial
0578
Aircraft time
75,603 hours, 9,874 cycles
Part
Fault Message
Condition
Illuminated
Location
Lt Aft Door
Stage of operation
IN
How discovered
9
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ECAM MESSAGE/CAUTION DOOR L AFT CABIN ANNUNCIATED AT FL 410 PRESSURE NORMAL DIF 8.6. PERFORMED ECAM + QRH TO LIGHTS OUT NO PRESSURE PROBLEMS. CORRECTIVE ACTION: POST FLIGHT REPORT FAULTS PROX SENSOR (23MJ)/PROX SENSOR(25MJ)/PSCU(5MJ). T/S REF A330 TSM 52-13-00-810-803-A. FAULT CLEARED. NO FAULT DETECTED DURING GND SCANNING AND PSCU TEST OK.