What was found
CORROSION FLOOR STRUCTURE BEAM LOCATED BETWEEN FR 64 TO FR 66 AND AT -Y512 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM, PER A320 SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FLOOR STRUCTURE BEAM LOCATED BETWEEN FR 64 TO FR 66 AND AT -Y512 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM, PER A320 SRM 51-42-11.