What was found
SHIP 3235 CORROSION ANGLE WEB FLOOR STRUCTURE LOCATED FR69 TO FR70 AND STR23R AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED ANGLE WEB PER A320 SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHIP 3235 CORROSION ANGLE WEB FLOOR STRUCTURE LOCATED FR69 TO FR70 AND STR23R AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED ANGLE WEB PER A320 SRM 51-72-11.