What was found
ER/A 560974-14AD REV D ISSUED FOR REPAIRS TO LOWER FIXED LE ON VERTICAL STAB. ACCOMPLISH ER/A 560974-14AD REV D SECTION III REPEAT INSPECTIONS EVERY 3,000FC FOLLOWING THE ACCOMPLISHMENT OF SECTION II (ACCOMPLISHED AT 53,271HRS AND 36,606CYC). ASSOCIATED ER/A 95-560974 ADDED FOR AC 9507. REF ER/A 561912-14 REV C AND LP #1776790 FOR ALL REQUIRED FOLLOW ON ACTION. ASSOCIATED AA 5530-01048 ADDED FOR AC 9507. TERMINATED LOG PER LINE 4 COMMENTS AND ER/A 560974-14AD. CLOSED LOG AND REMOVED MONITOR INSP PER ALERT 27APR21 AND LOG COMMENT. (LP #1777434)