What was found
SHIP 6716 - ATB- DUE TO FSEU SENSOR 1 C/B POPPING WITH ASSOCIATED FLAP/SLAT EICAS MESSAGE. CORRECTIVE ACTION: T/S PER B757 WDM 27-51-41. DISCONNECTED D2984 AND MEGGED FROM PMS 1&2 TO D3312B E3,F3 FOUND SHORT ON PIN 1, DISCONNECTED D41392P AND FOUND SHORT IN PYLON STRUT BOT (LT) ON WIRE W338621024R. REPAIRED WIRE PER SWPM CH. 20 AND B757 WDM 27-51. RECONNECTED AFTER REPAIR, PERFORMED AUTOLAND CHECKS.