As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHIP 685 INITIAL INSPECTION: CORROSION ON FRAME UPPER CHORD STA 365 FROM 0/63 RLBL AT FLOOR STRUCTURE AREA . CORRECTIVE ACTION: SUMMARY OF NRC 00551: FLOOR BEAM STA 365.25 LBL 12 TO RBL 70 WAS REPAIRED PER ER/A: 591694-14 REV.ORIGINAL. (1821540)