What was found
(LOG 7477588) RIGHT PACK LIGHT ILLUMINATED. UPON ENTRY OF A/C NOTICED A SLIGHT ODOR. STARTED APU . OPERATED PACKS, RIGHT PACK LIGHT ILLUMINATED. PERFORMED WORKCARD 0550-2001 ISOLATE SMOKE AND FUMES AND AFTER ODOR DETECTED PERFORMED AMM -00-01-100-801 OIL CONTAMINATION REMOVAL. SOME RESIDUAL OIL ON LEFT PACK CONDENSER, CLEANED AND RAN PACKS NO ODOR PRESENT. REPLACED RECIRC FILTERS PER AMM 21-25.