As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(LOG 1838175) DURING INSPECTION FOUND CRACK AND DEFORMED ON FWD FUSELAGE CUTOUT OF EXTERNAL POWER RECEPTACLE ACCESS DOOR. ELECTRICAL GROUND POWER RECEPTACLE SURROUND DOUBLER WAS REPAIRED PER B737-800 SRM 53-10-15-2R REPAIR 5 FIG. 203 AND REPAIR 4.