What was found
SHIP 663 DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGER (UPPER/LOWER SURFACES) BTW STA 640 TO 660 RBL 7.55, 10.45 AND 16.10 AT FWD CARGO COMPARTMENT. STRINGERS REPLACED. (LP 1854511)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHIP 663 DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGER (UPPER/LOWER SURFACES) BTW STA 640 TO 660 RBL 7.55, 10.45 AND 16.10 AT FWD CARGO COMPARTMENT. STRINGERS REPLACED. (LP 1854511)