What was found
SHIP 3232 ER/A 588785-14AD IS GENERATED FOR THE RH AFT SPAR TO PINTLE FITTING JOINT AT HOLE 16R. (CRACK) : CORRECTIVE ACTION: PER ER/A #588785-14AD REV.ORIGINAL. OK TO CONTINUE ON MONITOR. REPETITIVE INSPECTION IS REQUIRED 25,200 FLIGHT CYCLES OR 41,400 FLIGHT HOURS, WHICHEVER OCCURS FIRST, JOB COMPLETE. MONITOR CONTINUED. (1681751)