What was found
DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SHEAR CLIP STA 1219, STR 39L EVALUATED CORROSION ON SHEAR TIE IN AFT CARGO AT STA 1219, STR 39L AND STR 39R, FOUND OUT OF LIMITS. SHEAR TIE REPLACED PER SRM. (LP 1865563)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SHEAR CLIP STA 1219, STR 39L EVALUATED CORROSION ON SHEAR TIE IN AFT CARGO AT STA 1219, STR 39L AND STR 39R, FOUND OUT OF LIMITS. SHEAR TIE REPLACED PER SRM. (LP 1865563)