What was found
DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON NUT PLATE STA 1197+132 BL 13L AFT CARGO FLOOR BEAM. REPLACED INNER CHORD "TEE CAP" AT STA 1197+132 AFT CARGO FLOOR BEAM. (LP 1865936)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON NUT PLATE STA 1197+132 BL 13L AFT CARGO FLOOR BEAM. REPLACED INNER CHORD "TEE CAP" AT STA 1197+132 AFT CARGO FLOOR BEAM. (LP 1865936)