What was found
DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FAIL SAFE CHORD AT DRAIN HOLE BS 1562 BL 0 APPROX. WL 135 WHILE INVESTIGATION SHEAR TIE. HEAR TIE REPAIRED PER SRM 53-60-07. (LP 1781900)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FAIL SAFE CHORD AT DRAIN HOLE BS 1562 BL 0 APPROX. WL 135 WHILE INVESTIGATION SHEAR TIE. HEAR TIE REPAIRED PER SRM 53-60-07. (LP 1781900)