What was found
LEFT WING SLAT 4 HAS DENT IN UPPER SURFACE. PREPARED , TREATED AND APPLIED EPOXY PRIMER PER A 321 SRM 57-40-00-300-065 . MEASURED DENTED AREA AND FOUND WITHIN LIMITS PER A 321 SRM 57-40-00-283- 001 DEPTH = .167" / CHORD WISE DIMENTION = 5.01". REPAIRED DENT REF A321 SRM 57-40-00. THIS TEMPORARY FILLER REPAIR MUST BE REPLACED BY A PERMANENT STRUCTURAL REPAIR WITHIN 5 000 FC OR 10 000 FH OR 24 MONTHS, WHICHEVER OCCURS FIRST PER A321 SRM 57-40-00-300-065 STEP 2.A.(5) REMOVED #4 SLAT PER A321 AMM 27-84-66 AND REPAIRED SLAT PER A321 SRM 57-40-00-300-067 AND REINSTALLED #4 SLAT PER A321 AMM 27-84 -66 REF N/R 310. CLOSED LOG AND REMOVED MONITOR. (LP# 1296972)