As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHIP 3164 - CRACK INDICATION ON FRAME 16 RH SIDE INTERCOSTAL FITTING AT DOOR STOP 7 POSITION ON OPEN FASTENER HOLES 1 AND 3 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED INTERCOSTAL FITTING AT DOOR STOP 7 ON FRAME 16 RH SIDE AS PER SRM A319 51-72. (1933166)