What was found
SHIP 5644 EMERGENCY LAMPS AT DOOR 1R, 3R,3L, OVERWING EXIT AT 26A + SEAT 4C INOP. CORRECTIVE ACTION: FOUND BATTERY PACK M730 NOT FULLY SEATED. RESEATED SAME. LIGHTS AT 1R DOOR AND ROW 4C NOW OPS CHECK GOOD. NO TROUBLE FOUND AT 26A. RELAMPED LIGHTS AT DOOR 3L + 3R ALL OPS CHECK GOOD REF B757 AMM 33-51. (5364337)