What was found
SHIP 5635 DURING SVC CK FOUND RT O/W EXIT AND 26 TO 31DEF EMERGENCY LIGHTS INOP. CORRECTIVE ACTION: REMOVED AND REPLACED BATTERY AT 26 DEF FLOOR SIDE PANEL. RESET BATTERY TRAY. ALL LIGHTS TEST GOOD. REF. B757 AMM 33-51. (8084788)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHIP 5635 DURING SVC CK FOUND RT O/W EXIT AND 26 TO 31DEF EMERGENCY LIGHTS INOP. CORRECTIVE ACTION: REMOVED AND REPLACED BATTERY AT 26 DEF FLOOR SIDE PANEL. RESET BATTERY TRAY. ALL LIGHTS TEST GOOD. REF. B757 AMM 33-51. (8084788)