What was found
SHIP 3171 - SMELLED SMOKE NEAR THE AFT GALLEY. PERFORM WC 0550-2002 FOR IDENTIFY SMOKE SMELL. CHECKED LT ENG FRONT SPINNER FOR OIL LEAKS. CHECKED APU ENCLOSHER AND INLET FOR OIL LEAK'S WITH BLACK LIGHT, NO LEAKS. A/C OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHIP 3171 - SMELLED SMOKE NEAR THE AFT GALLEY. PERFORM WC 0550-2002 FOR IDENTIFY SMOKE SMELL. CHECKED LT ENG FRONT SPINNER FOR OIL LEAKS. CHECKED APU ENCLOSHER AND INLET FOR OIL LEAK'S WITH BLACK LIGHT, NO LEAKS. A/C OK FOR SERVICE.