As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFTER DOOR CLOSED AND APU BLEED ON, DIRTY SMOKE SMELL IN COCKPIT. COMPLIED WITH AMDS WORK CARD 0550-2002 UP TO STEP 8. STEP 8 NEEDS TO BE COMPLIED WITH. SOURCE OF SMOKE SMELL LEAKING APU FUEL CONTROL. ITEM NEEDS REPLACED.(063349)REMOVED AND REPLACED APU FUEL CONTROL UNIT PER A321 AMM 49-32, LEAK CK GOOD. COMPLIED WITH AMDS WORK CARD 4900-2001 UP TO STEP 5. NEEDS TO BE COMPLIED WITH COMPLETED WRK CARDS 49-2001 AND 0550- 2002.