What was found
CRACK INDICATION FOUND IN OPEN FASTENER HOLE (1EA) LOCATED AT UPPER AT TACHMENT FRAME 4 SIDE POST AREA LH SIDE, CRACK DIRECTION: 01 O CLOCK APPROX (D1-D2=0.0665 INCH). PERFORMED PERMANENT REPAIR ON UPPER ATTACHMENT FRAME 4 SIDE POST AREA LH SIDE AS PER ER/A 543312-14AD REV A, APPROVED DATE28/DEC /21 , PRI 543312-14AD REV 0, REV 1, ER/A 543312-14AD REV A HAS BEEN COMPLIED WITH PRI 543313-14AD REV 0 , REV 1, REV 2,MATCHES REPAIR INSTRUCTIONS ERA AND PRI ,SEE LOG PAGE FOR TIME CONTROLLED ITEMS SEC. IV , LOG PAGE 2067125 , SEC V, LOG PAGE2067128, AND SEC. DTE LOG PAGE 2067149. RII INSPECTION COMPLETE 0992822 AE237QC JOB COMPLETE. (LP# 2067361)