What was found
CRACK INDICATION FOUND IN OPEN FASTENER HOLE (1EA) LOCATED AT UPPER AT TACHMENT FRAME 4 SIDE POST AREA RH SIDE, CRACK DIRECTION: 07 O CLOCK ( D1-D2=0.075 INCH). PERFORMED PERMANENT REPAIR ON UPPER ATTACHMENT FRAME 4 SIDE POST AREA RH SIDE AS PER ER/A 543313-14AD REV A, APPROVED DATE27/DEC /21 PRI 543313-14AD REV 0, REV 1, REV 2, REV 3. ER/A 543313-14AD REV A HAS BEEN COMPLIED WITH PRI 543313-14AD REV 0 , REV1, REV 2, REV 3 MATCHES REPAIR INSTRUCCION ERA AND PRI . SEE LOG PAGE FOR TIME CONTROLLED ITEMS SEC. IV , LOG PAGE 2066672, SECV, LOG PAGE 2066678, AND SEC. DTE LOG PAGE 2066684 RII INSPECTION COMPLETE 0992822 AE237QC JOB COMPLETE. (LP#2067370)